Nikola Tesla Books
October 30-31
He continues measurements, which involve the primary coil of the big high frequency transformer, regulating coil and the inductance of the connections. The wiring scheme is shown on Oct. 30; except that the short circuit is established via a rotating arcing device and a capacitor. So only the above mentioned inductances remain in the circuit. The measurement method has been explained several times so far. As a new item it is explained how the signal of the frequency of approximately 140 Hz is produced and how the frequency measurement is performed.